    Counter Rotating Open Rotor Animation using Particle Image Velocimetry

    Full text link
    This article describes the two accompanying fluid dynamics videos for the "Counter rotating open rotor flow field investigation using stereoscopic Particle Image Velocimetry" presented at the 64th Annual Meeting of the APS Division of Fluid Dynamics in Baltimore, Maryland, November 20-22, 2011.Comment: Videos are include

    Progress in Developing Hybrid RPCs: GEM-like Detectors with Resistive Electrodes

    Full text link
    We have recently developed an innovative detector of photons and charged particles: a GEM-like gaseous amplification structure with resistive electrodes instead of commonly used metallic ones. This novel detector combines the best property of GEMs- the capability to operate in a cascaded mode and in poorly quenched gases - and of RPC: the protection against sparks. In this paper will shortly review our latest achievements in this direction, however the main focus will be given on a new advanced design that allows to build large area detectors manufactured by a screen printing technology. The proposed detector, depending on the applications, can operate either in a GEM mode (electron multiplications through holes only) or as a hybrid RPC with simultaneous amplifications in the drift region and in the holes. The possible applications of this new detector will be discussed

    Advances in the Development of Micropattern Gaseous Detectors with Resistive Electrodes

    Full text link
    We describe the most recent efforts made by various groups in implementing resistive electrodes in micropattern gaseous detectors with the aim to combine in the same design the best features of RPCs (for the example, their robustness and spark protection property) with the high granularity and thus the good position resolution offered by microelectronic technology. In the stream of this activity, we have recently developed two novel detectors with resistive electrodes: one was based on resistive micromeshes and the second one is a MSGC with resistive electrodes. We have demonstrated that the resistive meshes are a convenient construction element for various designs of spark protective detectors: RPCs type, GEM type and MICROMEGAS type. These new detectors enable to considerably enhance the RPC and micropattern detectors applications since they feature not only a high position resolution but also a relatively good energy resolution (25-30 persent FWHM at 6 keV) and, if necessary, they can operate in cascaded mode allowing the achievement of a high overall gas gain. The main conclusion from these studies is that the implementation of resistive electrodes in micropattern detectors makes them fully spark protected; on this basis we consider this direction very promising

    Approaches to calculate the dielectric function of ZnO around the band gap

    Get PDF
    Being one of the most sensitive methods for optical thin film metrology ellipsometry is widely used for the characterization of zinc oxide (ZnO), a key material for optoelectronics, photovoltaics, and printable electronics and in a range of critical applications. The dielectric function of ZnO has a special feature around the band gap dominated by a relatively sharp absorption feature and an excitonic peak. In this work we summarize and compare direct (point-by-point) and parametric approaches for the description of the dielectric function. We also investigate how the choice of the wavelength range influences the result, the fit quality and the sensitivity. Results on ZnO layers prepared by sputtering are presented

    Scatterometry reference standards to improve tool matching and traceability in lithographical nanomanufacturing

    Get PDF
    High quality scatterometry standard samples have been developed to improve the tool matching between different scatterometry methods and tools as well as with high resolution microscopic methods such as scanning electron microscopy or atomic force microscopy and to support traceable and absolute scatterometric critical dimension metrology in lithographic nanomanufacturing. First samples based on one dimensional Si or on Si 3 N 4 grating targets have been manufactured and characterized for this purpose. The etched gratings have periods down to 50 nm and contain areas of reduced density to enable AFM measurements for comparison. Each sample contains additionally at least one large area scatterometry target suitable for grazing incidence small angle X ray scattering. We present the current design and the characterization of structure details and the grating quality based on AFM, optical, EUV and X Ray scatterometry as well as spectroscopic ellipsometry measurements. The final traceable calibration of these standards is currently performed by applying and combining different scatterometric as well as imaging calibration methods. We present first calibration results and discuss the final design and the aimed specifications of the standard samples to face the tough requirements for future technology nodes in lithography

    Optical and structural characterization of Ge clusters embedded in ZrO2

    Get PDF
    The change of optical and structural properties of Ge nanoclusters in ZrO2 matrix have been investigated by spectroscopic ellipsometry versus annealing temperatures. Radio-frequency top-down magnetron sputtering approach was used to produce the samples of different types, i.e. single-layers of pure Ge, pure ZrO2 and Ge-rich-ZrO2 as well as multi-layers stacked of 40 periods of 5-nm-Ge-rich-ZrO2 layers alternated by 5-nm-ZrO2 ones. Germanium nanoclusters in ZrO2 host were formed by rapid-thermal annealing at 600-800 ∘C during 30 s in nitrogen atmosphere. Reference optical properties for pure ZrO2 and pure Ge have been extracted using single-layer samples. As-deposited multi-layer structures can be perfectly modeled using the effective medium theory. However, annealed multi-layers demonstrated a significant diffusion of elements that was confirmed by medium energy ion scattering measurements. This fact prevents fitting of such annealed structure either by homogeneous or by periodic multi-layer model

    An overview of the mid-infrared spectro-interferometer MATISSE: science, concept, and current status

    Full text link
    MATISSE is the second-generation mid-infrared spectrograph and imager for the Very Large Telescope Interferometer (VLTI) at Paranal. This new interferometric instrument will allow significant advances by opening new avenues in various fundamental research fields: studying the planet-forming region of disks around young stellar objects, understanding the surface structures and mass loss phenomena affecting evolved stars, and probing the environments of black holes in active galactic nuclei. As a first breakthrough, MATISSE will enlarge the spectral domain of current optical interferometers by offering the L and M bands in addition to the N band. This will open a wide wavelength domain, ranging from 2.8 to 13 um, exploring angular scales as small as 3 mas (L band) / 10 mas (N band). As a second breakthrough, MATISSE will allow mid-infrared imaging - closure-phase aperture-synthesis imaging - with up to four Unit Telescopes (UT) or Auxiliary Telescopes (AT) of the VLTI. Moreover, MATISSE will offer a spectral resolution range from R ~ 30 to R ~ 5000. Here, we present one of the main science objectives, the study of protoplanetary disks, that has driven the instrument design and motivated several VLTI upgrades (GRA4MAT and NAOMI). We introduce the physical concept of MATISSE including a description of the signal on the detectors and an evaluation of the expected performances. We also discuss the current status of the MATISSE instrument, which is entering its testing phase, and the foreseen schedule for the next two years that will lead to the first light at Paranal.Comment: SPIE Astronomical Telescopes and Instrumentation conference, June 2016, 11 pages, 6 Figure
    corecore